1, Large-size Flat Panel Detector
Self-developed 17 x17 inch flat panel detector, covering a wider shooting range for superior imaging.
2, Integrated Console (Standard).
The easy-to-use console can realize startup, shutdown, and manual exposure.
3, Built-in Design of Energy-storage High Voltage Generator.
Supports single-phase input voltage, and saves floor space.
4, Split Design of Rack and Table; Space Saving and Easy to Install.
Adopts a split design for the rack and table, facilitating easy movements and saving space.
Item | Technology Parameter | |
Generator | Model | 100E-32S |
Power source condition | Single phase, 220VAC | |
Output power | 32KW | |
Tube voltage | 40~125KV | |
Tube current | 10mA~400mA | |
Loading time | 1~6300ms | |
Current time product | 0.1~80mAs | |
Nominal output power | 32KW(100kV,320mA,0.1s) | |
Instantaneous power | 2.5KVA | |
Tube | Model | Toshiba E7239X |
Maximum X-ray tube voltage | 125KV | |
Nominal focal spot value | Small Focus 1.0mm Large Focus 2.0mm | |
Rotation speed | 2700rpm@50Hz 3200rpm@60Hz | |
Target anode angle | 16° | |
Permanent filtration | 0.9 mm Al@75kV | |
Anode heat content | 100 kJ (140 kHU) | |
X-ray tube assembly heat content | 900 kJ (1250 kHU) | |
Weight | 16 kg | |
Detector | Model | 50-4343-WD |
Scintillator | Csi | |
Image sensor | a-Si(Amorphous Silicon) TFT | |
Active area size | 428×428mm (17″×17″) | |
Active area pixel | 3072×3072 Pixels | |
Pixel pitch | 140 μm | |
Spatial resolution | 3.4 Lp/mm | |
A/D conversion | 16bits | |
DQE | ≥62% | |
Imaging time | 5 S | |
Preview time | 3 S | |
Ingress protection | IPX4 | |
Workstation Computer | CPU | I3 |
RAM | 4G | |
Hardware drive | 1 TB | |
OS | Windows 10 professional edition | |
Screen size | 23 inches | |
Resolution | 1920×1080 | |
DROC Software | Imaging processing | Exposure dose display&adjustment |
Zoom in/out, Rotation and Mirror | ||
Image Stitching | ||
Support VHS, TTA, TPLO and HD function | ||
Data interface and transmit | DICOM 3.0 standard | |
Support export PNG format Image | ||
Table | Column height | 1920mm ± 5% |
SID | 1050mm ± 5% | |
Table size (length * width) | 1200*650mm | |
Height of table to the ground | 730mm | |
Load bearing | 60kg | |
Table movement | Separable movement of the table. Four casters with pedal brake. | |
Pedal exposure break | Optional | |
Exposure control box | Standard |
Veterinarians utilize X-rays to assess lesions in various parts of an animal’s body, including the chest, abdomen, head, neck, spine, and limbs. Sedation is often employed to ensure the animal remains still, allowing for optimal positioning and clear images, which are crucial for an accurate diagnosis. X-rays are instrumental in detecting a range of conditions such as foreign bodies, tumors, heart abnormalities, megaesophagus, bladder and kidney stones, fractures, and diaphragmatic hernias.