1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
6)Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report.
Input mode: | Floating and defibrillation protection |
Frequency response: | 0.05Hz ~ 150Hz(-3dB~+0.4dB) |
CMRR: | >60dB, >100dB(add filter) |
Time constant: | ≥ 3.2s |
Patient leak current: | <10µA |
Calibration voltage: | 1mV |
Sensitivity: | 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2% |
Noise level: | <15µVp-p |
Input circuit current: | ≤50nA |
Input impedance: | ≥50MΩ |
Sampling accuracy: | 12-bit |
Safety classification: | Class I, type CF and defibrillation-proof applied part |
Recording mode: | Thermal printing system |
Auto record: | Set record according to auto record format and mode, automatically switching leads, measuring and analyzing. |
Rhythm record: | Set record according to rhythm record format and mode, automatically measuring and analyzing. |
Manual record: | Set record according to record format, manually switching leads. |
Measurement parameters: | HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) |
Paper size: | 80mm(W)×20m(L) |
Sampling frequency: | 1000Hz |
EMG interference filter: | 25Hz/35Hz (-3dB) |
Power frequency filter: | AC 50Hz/60Hz(-20dB) |
Paper speed: | Auto: 25, 50mm/s, ±5%; Rhythm: 25, 50mm/s, ±5%; Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5% |
Power supply: | AC: 100V~240V(50/60Hz); DC: 7.4V/3500mAh rechargeable lithium battery |
Fuse specification: | Two AC time lag fuse(φ5×20mm), T1.6AL250V |
Waterproof degree: | IPX0 |
Working mode: | Continuous working |
Used for dog ,cat and other pet ECG testing.