Best Veterinary Equipment & Consumables In China

Sale!

IP-V710 infusion pump for veterinary

vet infusion pump, easy to use

IP-710 Infusion pump is small, light and easy to use.

$ 349.00

SKU IP-V710 Category

984165131

Availability: 10000 in stock (can be backordered)

1, Double CPU safer Injection

2, Occlusion pressure release function specially good for the small vet

3, Big Brightness LCD display visually

4, Occlusion, Air-in-Line, Audio Visual Alarm Volume:10 settings

5, Numeric Keypad very user friendly

6, 2200mAh Lithium Battery Backup life: ≥ 8Hours

Item

Specification

Infusion Mode 

Volume Mode,Time Mode,Drug Mode,Bolus Mode 

Rate Unit 

ml/h,volume/time,d/min

IV Sets

Standard single use IV sets (10,15,20,60d/ml, with diameter 3.4 – 4.5mm)

Flow Rate

1.0 ml/h-1200ml/h; 1.0d/min-400d/min 

Increment 

1.0-99.9ml/h with 0.1ml/h; 100-1200ml/h with 1ml/h 

Deviation 

Flow Rate: ≤5% (after calibration)

VTBI 

0.1-9999.9 ml 

Total Volume 

0-9999.9 ml 

Time 

1min – 99h59min

Purge Rate 

600ml/h, displaying purge volume

KVO 

0.1ml/h-5.0ml/h, adjustable

Keypad

Numeric Keypad, user friendly

BOLUS 

Bolus function available,flow rate adjustable

Night Mode 

Night Mode, No operation for 5mins, LCD brightness lower automatically.

Occlusion Pressure

Occlusion pressure detection , 40- 130KPa ,0-9 levels adjustable.

Detection 

dynamic pressure value display. 

Air bubble Detection

Ultrasonic detection, ≥50µL,Single bubble volume: 50 -300µ1,0-9 levels adjustable. 

Volume 

0-9 levels adjustable

Motor Anti-reverse Function

Anti-reverse function to prevent upstream 

IV Set

Open System. Can accept all kinds of IV Set after calibration

Self-Testing 

Self-Testing when start up and during infusing

Audio Visual  Alarm Message

 Air bubble, occlusion, door open, infusion finish, standby time expired, battery low, battery empty, battery disengaged, AC Power disengaged, motor error, pump error, pressure sensor error, parameter error, system abnormal

Screen

3.2’brightness LCD

Power Supply

AC: 100V – 240V, 50Hz/60Hz, ,≤ 25VA

Battery

Rechargeable Lithium battery: DCll.lV, 2200mAh;operating time: ≥8 hours
@25ml/h, displaying remaining battery

Operation Condition

Temperature:S°C-40°C,Relative humidity:20% – 80% ,Atmospheric pressure:70-106KPa

Transportation & Storage

Temperature:-20°C-55°C,Relative humidity:10% – 95% ,Atmospheric pressure:S0-106KPa

Classification

Type CF,Class I , IPX3,IS013485,CE,IEC60601

Dimension

145mm x 150mm X200mm

Weight

1.7kg

veterinary infusion pump application
veterinary infusion pump application

contact us


Follow us

Scroll to Top