Vincent IP-710C veterinary infusion pump features a classic vertical design, optimized for ease of use in veterinary hospitals. With a software compensation error margin within ±5% after calibration, it ensures precise and reliable fluid delivery. The pump includes adjustable level settings and an occlusion pressure release function for added safety and flexibility in various treatment scenarios. Equipped with a dual-CPU system for enhanced performance and safety, the pump also features a numeric keypad, making it user-friendly and efficient for veterinary professionals.
Adjustable Levels Setting | 10 levels setting for occlusion and air bubble volume |
Strong Battery Backup | 3000mAh battery and backup time more than 10 hours |
User Friendly | Big Screen and numeric keypad |
Occlusion Release Function | Occlusion pressure release and restarting function |
Infusion Mode | Volume mode, time mode |
Item | Specification |
Infusion Mode | Volume Mode, Time Mode, Drug Mode |
Rate Unit | ml/h, volume/time, d/min |
Iv sets | Standard single use IV sets (10,15,20,60d/mL, with diameter 3.4-4.5mm) |
Flow Rate | 1.0ml/h~1200ml/h |
Increment | 1.0-99.9 ml/hin 0.1ml/h step, 100-1200ml/in 1ml/h step |
Deviation | Flow Rate: ≤5% (after calibration) |
VTBI | 0.1~9999.9 ml |
Total Volume | 0.0~9999.9 ml |
Time | 1min~99h00min |
Purge Rate | 600ml/h, display purge volume |
KVO | 1.0 ml/h~5.0 ml/h, adjustable |
Keypad | Numeric keypad |
BOLUS | Bolus function available, flow rate adjustable |
Night Mode | Screen to be dim automatically in 5 mins after standby time expired. |
Occlusion pressure detector | Occlusion pressure detection, 40KPa~130KPa.10 levels adjustable with dynamic pressure value display |
Air Bubble Detector | Ultrasonic detection, ≥50ul, Single bubble volume: 50~300ul, 10 levels adjustable. |
Volume | 8 levels adjustable |
Motor Anti-reverse Function | Anti-reverse function and real-time monitoring |
IV Set Management | Open system, accept different IV brands after calibration |
Self-Testing | Self-testing before startup and during infusion |
Audio Visual Alarm Message | Air bubble, occlusion, door open, infusion finish, standby time expired, battery low, battery empty, battery disengaged, AC Power disengaged, motor error, pump error, air sensor error, parameter error, system error, lV not calibrated. |
Screen | 3.2-inch brightness LCD |
Power supply | AC Power:100V~240V, 50Hz/60Hz, ≤25VA |
Battery | Rechargeable Lithium battery, DC:11.1V, 3000mAh: operating time: ≥10h @25ml/h, displaying remaining battery. |
Operation Condition | Temperature: +5°C~+40°C, Humidity: 20%~90%, Air pressure: 70~106 KPa |
Transport & Storage | Temperature : -20℃~+55℃, Humidity: 10%~95%, Air pressure:70~106 KPa. |
Classification | Type CF, Class, IPX3 |
Dimension | 145mmx150mmx200mm; Weight: 1.7 kg. |